文章摘要

自体血回输对心瓣膜置换手术患者血栓弹力图和纤溶指标的影响

作者: 1范迪堃, 1韩冬, 1张壮
1 南阳市中心医院心胸外科,河南 南阳 473000
通讯: 范迪堃 Email: 9928234@qq.com
DOI: 10.3978/j.issn.2095-6959.2020.03.018

摘要

目的:探讨体外循环(extracorporeal circulation,ECC)自体血回输对心脏瓣膜置换手术患者血栓弹力图(thrombelastogram,TEG)、纤溶指标的影响。方法:选取2016年7月至2017年12月在南阳市中心医院接受ECC自体血回输对心脏瓣膜置换手术患者63例,其中研究组30例患者采用自体血回输技术、对照组33例患者采用库存血输血;对比两组患者手术前后的血红蛋白(Hb)、红细胞压积(hematocrit,Hct)、血小板(platelet,PLT)、凝血酶原时间(prothrombin time,PT)、凝血活酶时间(activated partial thromboplastin time,APTT)、凝血酶时间(thrombin time,TT)、纤维蛋白原降解产物(fibrinogen degradation product,FDP)、D-二聚体(D-D)、前列腺素E2(PGE2)、血小板α-颗粒膜蛋白(GM-140)及TEG参数的变化。结果:术前,两组患者的Hb,Hct测定值差异无统计学意义(P>0.05);术后24 h,研究组患者的Hb,Hct测定值显著高于对照组(P<0.05);术前,两组患者的PLT,PT,APTT,TT水平差异无统计学意义(P>0.05);术后24 h,研究组患者的PT,APTT测定值显著低于对照组(P<0.05);术前,两组患者的FDP,D-D,PGE2,GM-140测定值差异无统计学意义(P>0.05);术后24 h,研究组患者的FDP,D-D,PGE2,GM-140测定值显著低于对照组(P<0.05);术前,两组患者的R值、K值、MA值、α角差异无统计学意义(P>0.05);术后24 h,研究组患者的R值、K值显著低于对照组(P<0.05),研究组患者的MA值、α角显著高于对照组(P<0.05)。结论:ECC自体血回输对心脏瓣膜置换手术患者的凝血功能、TEG参数及纤溶系统稳定性影响更小。
关键词: 体外循环;自体血回输;心脏瓣膜置换手术;血栓弹力图;纤溶指标

Effect of autologous blood transfusion on thrombelastogram and fibrinolysis indexes in patients undergoing cardiac valve replacement surgery

Authors: 1FAN Dikun, 1HAN Dong, 1ZHANG Zhuang
1 Department of Cardiothoracic Surgery, Nanyang Central Hospital, Nanyang Henan 473000, China

CorrespondingAuthor: FAN Dikun Email: 9928234@qq.com

DOI: 10.3978/j.issn.2095-6959.2020.03.018

Abstract

Objective: To investigate the effect of extra cardiac valve replacement surgery (ECC) on blood vessel thrombus (TEG) and fibrinolysis in patients undergoing cardiac valve replacement surgery. Methods: From July 2016 to December 2017, 63 patients underwent ECC in our hospital, including 30 patients with autologous blood transfusion technique (the study group) and 33 patients with stored blood (the control group). Hemoglobin (Hb), hematocrit (Hct), platelet (PLT), prothrombin time (PT), thromboplastin time (APTT), thrombin time (TT), fibrinogen degradation product (FDP), D-dimer (D-D), prostaglandin E2 (PGE2), platelet alpha-granule membrane protein (GM-140), and TEG parameters before and 24 h after surgery were compared between the two groups. Results: Before operation, the difference of Hb and Hct between the 2 groups was not statistically significant (P>0.05). At 24 hours after operation, the Hb and Hct values of the study group were significantly higher than those of the control group (P<0.05). Before operation, the differences of PLT, PT, APTT and TT levels between the two groups were not statistically significant (P>0.05). The PT and APTT values of the study group were significantly lower than those of the control group at 24 hours after operation (P<0.05). Before surgery, the difference of FDP, DD, PGE2 and GM-140 between the two groups were not statistically significant (P>0.05). The value was significantly lower than that of the control group (P<0.05). There was no significant difference in the R value, K value, MA value and α angle between the two groups before surgery (P>0.05). The R and K values were significantly lower than those in the control group (P<0.05) at 24 hours after operation. The MA value and α angle of the study group were significantly higher than those of the control group (P<0.05). Conclusion: ECC autologous blood transfusion has less effect on coagulation function, TEG parameters and stability of fibrinolytic system in patients undergoing cardiac valve replacement surgery.
Keywords: extracorporeal circulation; autologous blood transfusion; heart valve replacement surgery; thromboelastography; fibrinolysis index

文章选项